1295 Morningside Avenue,
Unit 16/17
Toronto, ON M1B 4Z4
Canada
 Phone: 416-261-4865
 Fax: 416-261-7879
 
 
 
Food & Beverage  
Healthcare  
Pharmaceutical  
Environmental  
Manufacturing  
Agriculture  
 

Novus TxIsoPack and TxIsoRail HART Temperature Transmitters - NV-8808000100/NV-8808010100

Novus TxIsoPack and TxIsoRail HART Temperature Transmitters
(click image to enlarge)

Novus TxIsoPack and TxIsoRail HART Temperature Transmitters
Price: USD 279.00 (CAD 376.65) Estimated Price
Part #: NV-8808000100/NV-8808010100

The TxIsoPack-HART and TxIsoRail-HART are high performance temperature transmitters which convert RTDs, Thermocouples and voltage signals into a 4-20 mA current along with a superimposed HART protocol digital communication. Complete configuration, calibration and parameters monitoring can be fully achieved through the two-wire current loop by means of a convenient PC software and USB interface called TxConfig-HART. Sensor type input is fully programmable for most relevant RTDs, thermocouples, variable resistors, and voltage in mV. High Isolation between input and output drastically improves stability and reliability with greater immunity to electromagnetic noises in extremely harsh industrial environments.

Features & Specifications:

  • TxIsoPack-HART for Head Mount applications
  • TxIsoRail-HART for DIN Rail Mount applications
  • Programmable Input:  
        - Thermocouples B, E, J, K, R, S, T, N
        - Pt100, Pt500, Pt1000
        - Cu50, Cu100
        - Ni100, Ni500, Ni1000 (5000 ppm / K)
        - Ni100, Ni500, Ni1000 (6180 ppm / K)
        - 0 to 400 Ω, 0 to 2000 Ω, 0 to 10 KΩ
        - 10 to 75 mV, -100 to 100 mV, -100 to 500 mV, -100 to 2000 mV  
  • User programmable working range  
  • 2-wire loop powered 4-20 mA output  
  • 2, 3 or 4-wire RTD and  thermocouples with linear output  
  • Cold junction compensation for thermocouples  
  • Configuration on a PC with the TxConfig-HART interface  
  • Selectable digital filter for input signal  
  • Power: 10.5 to 35  Vdc  
  • Accuracy: Pt100 and 0 to 50 mV ± 0.2 % full scale.  Thermocouples ± 0.3 % max. of full scale  
  • Working temperature: -40 to +85 °C (-40 to 185°F)  
  • Programmable sensor failure detection for upscale or downscale  
  • Resolution: 0.3 µA  
  • Maximum load: (V Power - 10.5 V) / 0.022 A  
  • Galvanic isolation: 1.5 KV

 

Required Accessories:
Technical Information:
Additional Information:
Part# Description Price USD$
NV-8808000100 TxIsoPack-HART Program, 2-Wire Isolated Head Mount Temp.Transmit. 4-20mA out $279.00
NV-8808010100 TxIsoRail-HART Program, 2-Wire Isolated DIN Rail Mount Temp.Transmitter 4-20mA out $310.00
NV-8816031059 TxConfig HART (software configurator HART + interface USB) $460.00
PLEASE NOTE: No payment is involved, this system is designed to give you an online quote only, please call 416-261-4865 or fax 416-261-7879 if you would like to place an order. 
 