This Waterproof Industrial Gen 2 Thermocouple Sensor is available with optional K-Type connector to measure high temperature applications. It can be user programmed for a user-given time interval (heartbeat) and transmit the data to the gateway. See optional probes or contact us for options.
Features:
Specifications:
| 
   Temperature
  Measurement  | 
   Range – Full K-Type
  capability  | 
   -200°C to
  1250°C (-328°F to 2282°F)  | 
| 
   Range – Quick
  Connect Probe  | 
   -50°C to
  260°C (-58°F to 500°F)  | |
| 
   Accuracy above
  0°C (32°F)  | 
   ± 2.2°C
  (±4°F) or 0.75% (whichever is greater)  | |
| 
   Accuracy
  below 0°C (32°F)  | 
   ± 2.2°C
  (±4°F) or 2.0% (whichever is greater)  | |
| 
   Resolution  | 
   0.1°C
  (0.18°F)  | |
| 
   Response time  | 
   50 seconds
  (10-second time constant)1  | |
| 
   Quick Connect
  Probe & Cable  | 
   Probe
  characteristics  | 
   Pointed 15 cm
  (6") quick connect stainless steel probe  | 
| 
   Probe
  connector  | 
   k-type mini
  (flat) male  | |
| 
   Cable
  dimensions  | 
   Waterproof
  high-temperature ABS with EMF shielding  | |
| 
   Cable
  material  | 
   Retractable
  yellow TPE jacket  Maximum
  Operating Temperature: 104°C (220°F) 500% expansion or 1.5m (5') stretch  | |
| 
   Cable
  connector  | 
   K-Type mini
  (flat) female  | |
| 
   Gen 2
  Wireless  | 
   Data logging  | 
   Sensor logs
  2000 to 4000 readings if gateway connection is lost (non-volatile flash,
  persists through power cycling): 10-minute Heartbeats = ~22 days - 2-hour
  Heartbeats = ~266 days  | 
| 
   | 
   Wireless
  protocol  | 
   Gen 2
  Proprietary Frequency-Hopping Spread Spectrum (FHSS)  | 
| 
   | 
   Wireless
  transmission power (EIRP)  | 
   50 mW
  (900MHz), 25 mW (868 MHz), 10 mW (433 MHz)  | 
| 
   | 
   Wireless
  range  | 
   2,000+ ft.
  through 18+ walls with Gen 2 XL ® Gateway  | 
| 
   | 
   Security  | 
   Encrypt-RF ®
  (256-bit key exchange and AES-128 CTR)  | 
| 
   General  | 
   Battery
  voltage range  | 
   2.0 to 3.8 VDC  | 
| 
   | 
   Operating
  altitude (non-pressurized environments)  | 
   -15.2 to
  1,982 m (-50 to 6,500 ft)2  | 
| 
   | 
   Storage
  altitude (non-pressurized environments)  | 
   -15.2 to
  3,048 m (-50 to 10,000 ft)2  | 
| 
   | 
   Operating
  humidity  | 
   5 to 85% RH
  (non-condensing)  | 
| 
   | 
   Certifications  | 
   900 MHz
  sensors: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.  | 
 
| 
   1. Response time defined as five time constants for
  99.3% of actual temperature.  2. Operating and storage altitude without DC power
  supply is -30.48 to 9144 m (-100 to 30000 ft).  | 
 ||
* Hardware cannot
withstand negative voltage. Please take care when connecting a power device. 
** At temperatures