Wireless Industrial Gen 2 Air Velocity / Speed Sensor


  • Part #:RFI-0290-2
  • Weight:3.7 oz
  • Dimensions:3.7 x 2.32 x 1.38
  • Units:Inches
  • Availability: Inquire

Price: $567.00
Price: $765.45


Description

The Wireless Industrial Gen 2 Industrial Air Velocity / Speed Sensor measures the pressure difference between two input ports, the temperature, and altitude determines the speed at which the air is moving in a system and transmits the measurement to Scigiene Premiere. The sensor measures the pressure difference between two ports. When viewing the sensor from the top, the right inlet port is the negative or low side pressure input. When the pressure on this port is greater than the left port the sensor produces a negative pressure reading. When the pressure is greater on the left port the sensor produces a positive pressure reading. Combined with the temperature and the altitude, the sensor determines at what rate the air is flowing in a system.

Features:

  • Wireless range of 1,200+ feet through 12+ walls
  • Frequency-Hopping Spread Spectrum (FHSS)
  • Best-in-class interference immunity
  • Best-in-class power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Data logs 2000 to 4000 readings if the gateway connection is lost (non-volatile flash, persists through the power cycle): 10-minute heartbeats = ~ 22 days, 2-hour heartbeats = ~ 266 days
  • Over-the-air updates (future-proof) 

Specifications:

Supply voltage

2.0-3.8 VDC (3.0-3.8 VDC using power supply) 

Current consumption

0.2 μA (sleep mode), 0.7 μA (RTC sleep), 570 μA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode)

Operating temperature range (board circuitry and battery)

-40°C to 85°C (-40°F to 185°F)

Included battery

Max temperature range

-40° to +85°C (-40° to +185°F)

Capacity

1500 mAh

Pressure Range

-500 Pa to 500 Pa

Accuracy

+/- 0.5 m/s

Resolution

0.1 ms

Allowable overpressure

100 kPa

Rated burst pressure

500 kPa

Max humidity for long-term exposure

40°C dew point

Range at 0 m Altitude

Range at 5000 m Altitude

Range at 8000 m Altitude

0-30m/s

0-40m/s

0-50m/s

Span repeatability

0.5% of reading

Span shift due to temperature variation

< 0.5% of reading per 10°C

Offset stability

< 0.05 Pa/year

Calibrated for

Air, N2

Media compatibility

Air, N2, O2, non-condensing

Temperature measurement range

-40°C to 85°C (-40°F to +185°F)

Calibrated temperature measurement range

0.1°C

Temperature resolution

0.1°C

Temperature accuracy

+/- 2°C (-10°C to +60°C)

+/- 3°C (-40°C to +85°C)

Temperature repeatability

+/- 0.1°C

Weight

4.7 ounces

Enclosure rating

NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof

UL rating

UL Listed to UL508-4x specifications (File E194432)

Certifications

900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.

 

Please call your Scigiene representative for help in designing your wireless system in order to make sure all range and other technical specifications are fully met.

Required Accessories

Scigiene 21 CFR Part 11 Premiere is a secure cloud based monitoring and notification software dedica (more...)

Part #: RFR-0539-2
$519.75 (USD)
$701.66 (CAD)
The Scigiene GEN 2 4G Industrial Cellular Gateway allows you to control GEN 2 Wireless Sensor settin (more...)

Part #: RFR-0538-2
$404.25 (USD)
$545.74 (CAD)
The Scigiene GEN 2 4G Cellular Gateway allows you to control GEN 2 Wireless Sensor settings without (more...)

Part #: RFR-0526-2
$231.00 (USD)
$311.85 (CAD)
The Gen 2 Ethernet Gateway allows your RF Wireless Sensors to communicate with the Scigiene Premier (more...)

Part #: RFR-0529-2
$288.75 (USD)
$389.81 (CAD)
The GEN2 Modbus Gateway acts as a data concentrator for Scigiene’s GEN 2 long range wireless sensor (more...)